Máy phát hiện khí đa năng
- Mã sản phẩm: 3-7404-01
- Quy cách (Đóng gói): 1 box
- Giá nhà sản xuất: 42,163,000 ¥
Đặc tính và thông số kỹ thuật
Model number: XP302M-A-1
Mass (g): Approximately 870 (including battery)
Size (mm): 152 x 152 x 42
Detection target gas: Combustible gas (methane or isobutane*)
▼Detection principle: Catalytic combustion type
▼Gas sampling method: Automatic Suction
▼Detection range (service range): 0 – 100% LEL
▼Alarm method: Buzzer (90dB or more), LCD display flashing, red color lamp flashing
▼Main function: Automatic back light, zero adjustment, peak hold, volume adjustment, flow rate drop sensing (pressure sensor), data logging, buzzer stop, alarm test, battery remaining amount display, temperature/clock display
▼Explosion-proof structure: Intrinsically safe structure ExibdII BT3 (combustible gas sensor unit is pressure explosion-proof structure)
▼Power supply: AA alkaline dry cell x 4 (included for test)
▼Accessories: 1m gas introduction tube (with drain filter), suction pipe, leather case
Detection target gas: Oxygen
▼Detection principle: Galvanic battery type
▼Gas sampling method: Automatic Suction
▼Detection range (service range): 0 – 25.0vol% (25.1 – 50vol%)
▼Alarm method: Buzzer (90dB or more), LCD display flashing, red color lamp flashing
▼Main function: Automatic back light, zero adjustment, peak hold, volume adjustment, flow rate drop sensing (pressure sensor), data logging, buzzer stop, alarm test, battery remaining amount display, temperature/clock display
▼Explosion-proof structure: Intrinsically safe structure ExibdII BT3 (combustible gas sensor unit is pressure explosion-proof structure)
▼Power supply: AA alkaline dry cell x 4 (included for test)
▼Accessories: 1m gas introduction tube (with drain filter), suction pipe, leather case
Detection target gas: Hydrogen sulfide
▼Detection principle: Controlled-potential electrolysis type
▼Gas sampling method: Automatic Suction
▼Detection range (service range): 0 – 30.0ppm (30.1 – 150ppm)
▼Alarm method: Buzzer (90dB or more), LCD display flashing, red color lamp flashing
▼Main function: Automatic back light, zero adjustment, peak hold, volume adjustment, flow rate drop sensing (pressure sensor), data logging, buzzer stop, alarm test, battery remaining amount display, temperature/clock display
▼Explosion-proof structure: Intrinsically safe structure ExibdII BT3 (combustible gas sensor unit is pressure explosion-proof structure)
▼Power supply: AA alkaline dry cell x 4 (included for test)
▼Accessories: 1m gas introduction tube (with drain filter), suction pipe, leather case
Detection target gas: Carbon monoxide
▼Detection principle: Controlled-potential electrolysis type
▼Gas sampling method: Automatic Suction
▼Detection range (service range): 0 – 150ppm (151 – 300ppm)
▼Alarm method: Buzzer (90dB or more), LCD display flashing, red color lamp flashing
▼Main function: Automatic back light, zero adjustment, peak hold, volume adjustment, flow rate drop sensing (pressure sensor), data logging, buzzer stop, alarm test, battery remaining amount display, temperature/clock display
▼Explosion-proof structure: Intrinsically safe structure ExibdII BT3 (combustible gas sensor unit is pressure explosion-proof structure)
▼Power supply: AA alkaline dry cell x 4 (included for test)
▼Accessories: 1m gas introduction tube (with drain filter), suction pipe, leather case
*Please specify either methane or isobutane if using combustible gas.